制造商TE Connectivity Corcom Filters
記錄 512
頁面 7/18
圖片 |
型號 |
制造商 |
描述 |
庫存 |
數量 |
系列 | 過濾器類型 | 配置 | 電壓-額定直流 | 電壓-額定交流電 | 電壓-額定交流電(相接地/中性) | 電壓-額定交流電(相間) | 當前 | 頻率-運行 | 應用程序 | 批準 | 工作溫度 | 安裝類型 | 終結符樣式 | 電感 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VDC/VAC 10A CHASS |
7,632 |
|
SB | Single Phase | Single Stage | 250V | 250V | - | - | 10A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | 1.1mH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VDC/VAC 6A CHASS |
6,858 |
|
SB | Single Phase | Single Stage | 250V | 250V | - | - | 6A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 1mH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 2A CHASS MNT |
5,562 |
|
K | Single Phase | Single Stage | - | 250V | - | - | 2A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 539µH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 20A CHASS MNT |
4,716 |
|
B | Single Phase | Single Stage | - | 250V | - | - | 20A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 440µH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 5A CHASS MNT |
7,794 |
|
K | Single Phase | Single Stage | - | 250V | - | - | 5A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 516µH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 10A CHASS MNT |
4,482 |
|
K | Single Phase | Single Stage | - | 250V | - | - | 10A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | IEC 320-C14, Quick Connect | 495µH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FLTR 277VDC/VAC 500MA CHASS |
7,488 |
|
FB | Single Phase | Single Stage | 277V | 277V | - | - | 500mA | 50/60Hz | Lighting | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Wire Leads | L1 - 890µH, L2 - 1.04mH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 3A CHASSIS MOUNT |
6,012 |
|
AYO | Three Phase (Wye) | Single Stage | - | - | 250V | 440V | 3A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | - |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 1A TH |
6,084 |
|
Z | Single Phase | Single Stage | - | 250V | - | - | 1A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Through Hole | PC Pins | 21.2mH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 125/280VAC 3.9A CHAS |
6,300 |
|
FL | Single Phase | Single Stage | - | 125V, 280V | - | - | 3.9A | 50/60Hz | Lighting | UL | -10°C ~ 40°C | Chassis Mount | Wire Leads | 180µH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 10A CHASS MNT |
8,694 |
|
R | Single Phase | Two Stage | - | 250V | - | - | 10A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 990µH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 6A CHASS MNT |
5,004 |
|
HZ | Single Phase | Single Stage | - | 250V | - | - | 6A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 5.1mH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 6A CHASS MNT |
6,336 |
|
RK | Single Phase | Single Stage | - | 250V | - | - | 6A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 5.1mH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 4A CHASS MNT |
6,426 |
|
HZ | Single Phase | Single Stage | - | 250V | - | - | 4A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 7mH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VDC/VAC 20A CHASS |
6,642 |
|
SB | Single Phase | Single Stage | 250V | 250V | - | - | 20A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | 900µH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 10A CHASS MNT |
6,948 |
|
RK | Single Phase | Single Stage | - | 250V | - | - | 10A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 4.97mH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 6A CHASS MNT |
3,924 |
|
SK | Single Phase | Single Stage | - | 250V | - | - | 6A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 8.73mH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 10A CHASSIS MOUNT |
4,086 |
|
AYO | Three Phase (Wye) | Single Stage | - | - | 250V | 440V | 10A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | - |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 6A CHASS MNT |
6,534 |
|
SK | Single Phase | Single Stage | - | 250V | - | - | 6A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | IEC 320-C14, Quick Connect | 8.73mH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 20A CHASS MNT |
8,622 |
|
DK | Single Phase | Single Stage | - | 250V | - | - | 20A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | 540µH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 10A CHASS MNT |
4,752 |
|
SK | Single Phase | Single Stage | - | 250V | - | - | 10A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 7.13mH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 6A CHASS MNT |
5,364 |
|
HT | Single Phase | Single Stage | - | 250V | - | - | 6A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 18.5mH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 6A CHASS MNT |
8,910 |
|
T | Single Phase | Single Stage | - | 250V | - | - | 6A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 18.5mH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 3A CHASS MNT |
5,184 |
|
Q | Single Phase | Two Stage | - | 250V | - | - | 3A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 32.18mH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 20A CHASS MNT |
8,622 |
|
SK | Single Phase | Single Stage | - | 250V | - | - | 20A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | 6.06mH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 3A CHASS MNT |
6,768 |
|
Q | Single Phase | Single Stage | - | 250V | - | - | 3A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | IEC 320-C14, Wire Leads | - |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 20A CHASS MNT |
6,084 |
|
R | Single Phase | Two Stage | - | 250V | - | - | 20A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 880µH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VDC/VAC 30A CHASS |
5,886 |
|
SB | Single Phase | Single Stage | 250V | 250V | - | - | 30A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | 900µH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 10A CHASS MNT |
4,122 |
|
T | Single Phase | Single Stage | - | 250V | - | - | 10A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 9.5mH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 30A CHASS MNT |
7,290 |
|
SK | Single Phase | Single Stage | - | 250V | - | - | 30A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (10-32) | 1.73mH |