系列 | 用於測量 | 技術 | 旋轉角度-電氣,機械 | 線性範圍 | 輸出 | 輸出信號 | 執行器類型 | 線性 | 電阻 | 電阻容差 | 電壓-供電 | 安裝類型 | 終結符樣式 | 工作溫度 | 包裝/箱 | 供應商設備包裝 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Alliance Sensors Group |
SENSOR LINEAR 6.35MM CABLE |
4,662 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 6.35mm (0 ~ 0.25") | 0 V ~ 10 V | - | Round Shaft | ±0.15% | - | - | 12V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 6.35MM CABLE |
5,976 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 6.35mm (0 ~ 0.25") | 4mA ~ 20mA | - | Round Shaft | ±0.15% | - | - | 18V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 12.7MM CABLE |
5,832 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 12.70mm (0 ~ 0.50") | 0 V ~ 10 V | - | Round Shaft | ±0.15% | - | - | 12V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 12.7MM CABLE |
3,598 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 12.70mm (0 ~ 0.50") | 4mA ~ 20mA | - | Round Shaft | ±0.15% | - | - | 18V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 19.05MM CABLE |
6,354 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 19.05mm (0 ~ 0.75") | 0 V ~ 10 V | - | Round Shaft | ±0.15% | - | - | 12V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 19.05MM CABLE |
4,950 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 19.05mm (0 ~ 0.75") | 4mA ~ 20mA | - | Round Shaft | ±0.15% | - | - | 18V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 25.4MM CABLE |
3,330 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 25.40mm (0 ~ 1.00") | 0 V ~ 10 V | - | Round Shaft | ±0.15% | - | - | 12V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 25.4MM CABLE |
2,934 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 25.40mm (0 ~ 1.00") | 4mA ~ 20mA | - | Round Shaft | ±0.15% | - | - | 18V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 50.8MM CABLE |
7,938 |
|
LR-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 50.80mm (0 ~ 2.00") | 4mA ~ 20mA | - | Round Shaft | ±0.15% | - | - | - | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 50.8MM CABLE |
2,466 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 50.80mm (0 ~ 2.00") | 0 V ~ 10 V | - | Round Shaft | ±0.15% | - | - | 12V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 50.8MM CABLE |
3,150 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 50.80mm (0 ~ 2.00") | 4mA ~ 20mA | - | Round Shaft | ±0.15% | - | - | 18V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 101.6MM CABLE |
7,776 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 101.60mm (0 ~ 4.00") | 0 V ~ 10 V | - | Round Shaft | ±0.15% | - | - | 12V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 101.6MM CABLE |
2,610 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 101.60mm (0 ~ 4.00") | 4mA ~ 20mA | - | Round Shaft | ±0.15% | - | - | 18V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 152.4MM CABLE |
5,904 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 152.40mm (0 ~ 6.00") | 0 V ~ 10 V | - | Round Shaft | ±0.15% | - | - | 12V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 152.4MM CABLE |
5,634 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 152.40mm (0 ~ 6.00") | 4mA ~ 20mA | - | Round Shaft | ±0.15% | - | - | 18V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 25.4MM CONNECTOR |
3,490 |
|
LRS-18 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 25.40mm (0 ~ 1.00") | 4mA ~ 20mA | - | Round Shaft | ±0.15% | - | - | - | Chassis Mount | Connector | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 203.2MM CABLE |
6,534 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 203.20mm (0 ~ 8.00") | 0 V ~ 10 V | - | Round Shaft | ±0.15% | - | - | 12V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 203.2MM CABLE |
7,668 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 203.20mm (0 ~ 8.00") | 4mA ~ 20mA | - | Round Shaft | ±0.15% | - | - | 18V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 254MM CABLE |
7,326 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 254.00mm (0 ~ 10.00") | 0 V ~ 10 V | - | Round Shaft | ±0.15% | - | - | 12V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 254MM CABLE |
2,808 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 254.00mm (0 ~ 10.00") | 4mA ~ 20mA | - | Round Shaft | ±0.15% | - | - | 18V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 304.8MM CABLE |
2,988 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 304.80mm (0 ~ 12.00") | 0 V ~ 10 V | - | Round Shaft | ±0.15% | - | - | 12V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 304.8MM CABLE |
3,816 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 304.80mm (0 ~ 12.00") | 4mA ~ 20mA | - | Round Shaft | ±0.15% | - | - | 18V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 381MM CABLE |
5,706 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 381.00mm (0 ~ 15.00") | 4mA ~ 20mA | - | Round Shaft | ±0.15% | - | - | 18V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 381MM CABLE |
3,348 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 381.00mm (0 ~ 15.00") | 0 V ~ 10 V | - | Round Shaft | ±0.15% | - | - | 12V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 457.2MM CABLE |
5,472 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 457.20mm (0 ~ 18.00") | 4mA ~ 20mA | - | Round Shaft | ±0.15% | - | - | 18V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 457.2MM CABLE |
3,598 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 457.20mm (0 ~ 18.00") | 0 V ~ 10 V | - | Round Shaft | ±0.15% | - | - | 12V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 12.7MM CONNECTOR |
6,750 |
|
GHS-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 12.70mm (0 ~ 0.50") | 4mA ~ 20mA | - | Round Shaft | ±0.15% | - | - | - | Chassis Mount | Connector | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 609.6MM CABLE |
2,412 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 609.60mm (0 ~ 24.00") | 4mA ~ 20mA | - | Round Shaft | ±0.15% | - | - | 18V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 609.6MM CABLE |
3,456 |
|
LZ-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 609.60mm (0 ~ 24.00") | 0 V ~ 10 V | - | Round Shaft | ±0.15% | - | - | 12V ~ 30V | Chassis Mount | Cable | -20°C ~ 85°C | Cylinder | - |
|
|
Alliance Sensors Group |
SENSOR LINEAR 50.8MM CONNECTOR |
2,790 |
|
GHS-19 | Linear Position | LVIT (Linear Variable Inductance Transducer) | - | 0 ~ 50.80mm (0 ~ 2.00") | 4mA ~ 20mA | - | Round Shaft | ±0.15% | - | - | - | Chassis Mount | Connector | -20°C ~ 85°C | Cylinder | - |