類別電源 / 電路保護 / 電氣,專業保險絲
制造商Eaton - Bussmann Electrical Division
記錄 6,921
頁面 166/231
圖片 |
型號 |
制造商 |
描述 |
庫存 |
數量 |
系列 | 保險絲類型 | 額定電流(安培) | 電壓額定值-AC | 電壓額定值-直流 | 響應時間 | 應用程序 | 功能 | 類別 | 批準 | 工作溫度 | 額定電壓下的分斷能力 | 安裝類型 | 包裝/箱 | 尺寸/尺寸 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Eaton - Bussmann Electrical Division |
2.54KV 12R BCLS FUSE |
7,200 |
|
BCLS | Cartridge | 230A | 2.54kV | - | - | Transformer Protection | - | - | UL | - | 50kA | Bolt Mount | Cylindrical, Blade Terminal (Bolt) | 3.000" Dia x 15.900" L (76.20mm x 403.86mm) |
|
![]() |
Eaton - Bussmann Electrical Division |
FUSE SQUARE 1.6KA 660V RECT |
3,186 |
|
* | Square | - | - | - | - | - | - | - | - | - | - | - | Rectangular, Blade | - |
|
![]() |
Eaton - Bussmann Electrical Division |
8.3KV 125E AHLE FUSE |
7,974 |
|
HLE | Cartridge | 125A | 8.3kV | - | - | Transformer Protection | - | - | - | - | 50kA | Holder | Cartridge, Non-Standard | 3.000" Dia x 15.900" L (76.20mm x 403.86mm) |
|
![]() |
Eaton - Bussmann Electrical Division |
8.3KV 150E AHLE FUSE |
5,454 |
|
HLE | Cartridge | 150A | 8.3kV | - | - | Transformer Protection | - | - | - | - | 50kA | Holder | Cartridge, Non-Standard | 3.000" Dia x 15.900" L (76.20mm x 403.86mm) |
|
![]() |
Eaton - Bussmann Electrical Division |
8.3KV 175E AHLE FUSE |
7,272 |
|
HLE | Cartridge | 175A | 8.3kV | - | - | Transformer Protection | - | - | - | - | 50kA | Holder | Cartridge, Non-Standard | 3.000" Dia x 15.900" L (76.20mm x 403.86mm) |
|
![]() |
Eaton - Bussmann Electrical Division |
FUSE CRTRDGE 1.2KA 1KVAC/800VDC |
5,868 |
|
FWJ | Cartridge | 1.2kA | 1kV | 800V | - | Electrical, Industrial | - | - | CE | - | 100kA | Bolt Mount | Cylindrical, Blade Terminal (Bolt) | 3.500" Dia x 6.811" L (88.90mm x 173.00mm) |
|
![]() |
Eaton - Bussmann Electrical Division |
FUSE CRTRDGE 1.4KA 1KVAC/800VDC |
5,418 |
|
FWJ | Cartridge | 1.4kA | 1kV | 800V | - | Electrical, Industrial | - | - | CE | - | 100kA | Bolt Mount | Cylindrical, Blade Terminal (Bolt) | 3.500" Dia x 6.811" L (88.90mm x 173.00mm) |
|
![]() |
Eaton - Bussmann Electrical Division |
FUSE CRTRDGE 1.8KA 1KVAC/800VDC |
8,514 |
|
FWJ | Cartridge | 1.8kA | 1kV | 800V | - | Electrical, Industrial | - | - | CE | - | 100kA | Bolt Mount | Cylindrical, Blade Terminal (Bolt) | 3.500" Dia x 6.811" L (88.90mm x 173.00mm) |
|
![]() |
Eaton - Bussmann Electrical Division |
FUSE CARTRIDGE 2KA 1KVAC/800VDC |
5,004 |
|
FWJ | Cartridge | 2kA | 1kV | 800V | - | Electrical, Industrial | - | - | CE | - | 100kA | Bolt Mount | Cylindrical, Blade Terminal (Bolt) | 3.500" Dia x 6.811" L (88.90mm x 173.00mm) |
|
![]() |
Eaton - Bussmann Electrical Division |
FUSE 250A 1200V 2SKN/140 AR DC |
3,816 |
|
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
![]() |
Eaton - Bussmann Electrical Division |
FUSE 7.2KV 224A 3"" MOTOR START |
7,524 |
|
- | Cartridge | 224A | 7.2kV | - | - | - | - | - | VDE | - | 63kA | Holder | Fuse Link | 2.992" Dia x 15.866" L (76.00mm x 403.00mm) |
|
![]() |
Eaton - Bussmann Electrical Division |
FUSE BUSS CURRENT LIMITER |
6,336 |
|
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
![]() |
Eaton - Bussmann Electrical Division |
FUSE BUSS CURRENT LIMITER |
3,096 |
|
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
![]() |
Eaton - Bussmann Electrical Division |
FUSE BUSS CURRENT LIMITER |
4,788 |
|
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
![]() |
Eaton - Bussmann Electrical Division |
FUSE SQUARE 2500A 660V RECT |
3,132 |
|
- | Square | 2.5kA | 660V | - | - | - | - | - | CSA, UL | - | - | - | - | - |
|
![]() |
Eaton - Bussmann Electrical Division |
FUSE CARTRIDGE 200A 4.8KVAC |
3,600 |
|
JCL-B | Cartridge | 200A | 4.8kV | - | - | Motor Protection | Indicating | R | UR | - | 50kA | Bolt Mount | Cartridge, Non-Standard | 17.88" Dia x 19.25" L (454.10mm x 488.90mm) |
|
![]() |
Eaton - Bussmann Electrical Division |
FUSE 17.5KV 150E DIN E RATE |
2,916 |
|
- | - | 150A | 17.5kV | - | - | - | - | - | - | - | - | Holder | Cartridge, Non-Standard | 3.465" Dia x 21.142" L (88.00mm x 537.00mm) |
|
![]() |
Eaton - Bussmann Electrical Division |
5.5KV 225E CLE FUSE |
8,856 |
|
CLE | Cartridge | 225A | 15.5kV | - | - | Transformer Protection | - | - | UL | - | - | Holder | Cartridge, Non-Standard | - |
|
![]() |
Eaton - Bussmann Electrical Division |
7.2KV 6R BCLS FUSE |
6,462 |
|
BCLS | Cartridge | 170A | 7.2kV | - | - | Transformer Protection | - | - | UL | - | 50kA | Bolt Mount | Cylindrical, Blade Terminal (Bolt) | 3.000" Dia x 15.900" L (76.20mm x 403.86mm) |
|
![]() |
Eaton - Bussmann Electrical Division |
5.5KV 125E HCL FUSE |
7,830 |
|
HLE | Cartridge | 125A | 5.5kV | - | - | Transformer Protection | - | - | UL | - | 65kA | Holder | Cartridge, Non-Standard | 3.000" Dia x 16.800" L (76.20mm x 426.72mm) |
|
![]() |
Eaton - Bussmann Electrical Division |
5.5KV 150E HCL FUSE |
6,102 |
|
HLE | Cartridge | 150A | 5.5kV | - | - | Transformer Protection | - | - | UL | - | 65kA | Holder | Cartridge, Non-Standard | - |
|
![]() |
Eaton - Bussmann Electrical Division |
5.5KV 200E HCL FUSE |
8,316 |
|
HLE | Cartridge | 200A | 5.5kV | - | - | Transformer Protection | - | - | UL | - | 65kA | Holder | Cartridge, Non-Standard | - |
|
![]() |
Eaton - Bussmann Electrical Division |
5.5KV 250E HCL FUSE |
3,348 |
|
HLE | Cartridge | 250A | 5.5kV | - | - | Transformer Protection | - | - | UL | - | 65kA | Holder | Cartridge, Non-Standard | - |
|
![]() |
Eaton - Bussmann Electrical Division |
FUSE MEDIUM VOLTAGE E-RATED |
5,850 |
|
* | Cartridge | 10A | 15.5kV | - | - | Transformer Protection | - | - | - | - | 50kA | Holder | Cartridge, Non-Standard | - |
|
![]() |
Eaton - Bussmann Electrical Division |
FUSE MEDIUM VOLTAGE E-RATED |
3,816 |
|
* | Cartridge | 15A | 15.5kV | - | - | Transformer Protection | - | - | - | - | 50kA | Holder | Cartridge, Non-Standard | - |
|
![]() |
Eaton - Bussmann Electrical Division |
FUSE MEDIUM VOLTAGE E-RATED |
5,472 |
|
* | Cartridge | 20A | 15.5kV | - | - | Transformer Protection | - | - | - | - | 50kA | Holder | Cartridge, Non-Standard | - |
|
![]() |
Eaton - Bussmann Electrical Division |
FUSE MEDIUM VOLTAGE E-RATED |
5,976 |
|
* | Cartridge | 30A | 15.5kV | - | - | Transformer Protection | - | - | - | - | 50kA | Holder | Cartridge, Non-Standard | - |
|
![]() |
Eaton - Bussmann Electrical Division |
5.08KV 12R BCLS FUSE |
3,348 |
|
BCLS | Cartridge | 230A | 5.08kV | - | - | Transformer Protection | - | - | UL | - | 50kA | Bolt Mount | Cylindrical, Blade Terminal (Bolt) | 3.000" Dia x 15.900" L (76.20mm x 403.86mm) |
|
![]() |
Eaton - Bussmann Electrical Division |
FUSE CARTRIDGE 150A 2.4KVAC |
6,912 |
|
JCK-A | Cartridge | 150A | 2.4kV | - | - | Motor Protection | Indicating | R | UR | - | 50kA | Holder | Cartridge, Non-Standard | 3.000" Dia x 10.8000" L (76.20mm x 274.00mm) |
|
![]() |
Eaton - Bussmann Electrical Division |
FUSE CARTRIDGE 1.8KA 600VAC CYL |
5,058 |
|
Limitron™ KLU | Cartridge | 1.8kA | 600V | - | Slow Blow | Electrical, Industrial | - | L | CE, CSA, UL | - | 200kA | Bolt Mount | Cylindrical, Blade Terminal (Bolt) | 3.500" Dia x 3.750" L (88.90mm x 95.25mm) |