類別傳感器 / 電流傳感器 / 電流傳感器
制造商Phoenix Contact
記錄 14
頁面 1/1
圖片 |
型號 |
制造商 |
描述 |
庫存 |
數量 |
系列 | 用於測量 | 傳感器類型 | 電流-感應 | 頻道數 | 輸出 | 靈敏度 | 頻率 | 線性 | 精度 | 電壓-供電 | 響應時間 | 電流-電源(最大值) | 工作溫度 | 極化 | 安裝類型 | 包裝/箱 | 供應商設備包裝 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Phoenix Contact |
CURRENT MEASURING TRANSDUCER |
8,082 |
|
- | AC | Transformer w/Conditioning | 1A, 5A (Selectable) | 1 | Ratiometric, 0 V ~ 10 V, 0 ~ 20mA | - | 45Hz ~ 60Hz | - | - | - | - | - | -25°C ~ 65°C | Bidirectional | DIN Rail | Module | - |
|
|
Phoenix Contact |
PACT RCP-4000A-1A-D140 |
5,382 |
|
- | AC | Transformer w/Conditioning | 100A ~ 4000A (Selectable) | 1 | Ratiometric, Voltage | - | 10Hz ~ 5kHz | ±0.5% | ±1% | 24V | - | - | 20°C ~ 70°C | Bidirectional | DIN Rail | Module | - |
|
|
Phoenix Contact |
PACT RCP-4000A-1A-D95 |
4,518 |
|
- | AC | Transformer w/Conditioning | 100A ~ 4000A (Selectable) | 1 | Ratiometric, Voltage | - | 10Hz ~ 5kHz | ±0.5% | ±1% | 24V | - | - | 20°C ~ 70°C | Bidirectional | DIN Rail | Module | - |
|
|
Phoenix Contact |
PACT RCP-4000A-1A-D190 |
3,708 |
|
- | AC | Transformer w/Conditioning | 100A ~ 4000A (Selectable) | 1 | Ratiometric, Voltage | - | 10Hz ~ 5kHz | ±0.5% | ±1% | 24V | - | - | 20°C ~ 70°C | Bidirectional | DIN Rail | Module | - |
|
|
Phoenix Contact |
SENSOR CURRENT HALL 55A AC/DC |
7,902 |
|
- | AC/DC | Hall Effect, Open Loop | 55A | 1 | Ratiometric, Voltage and Current | - | 15Hz ~ 400Hz | - | ±0.5% | 20V ~ 30V | 330ms (AC), 40ms (DC) | 50mA | -20°C ~ 60°C | Bidirectional | DIN Rail | Module | - |
|
|
Phoenix Contact |
PACT RCP-D140 |
4,428 |
|
- | AC | Transformer w/Conditioning | - | 1 | Ratiometric, Voltage | - | 40Hz ~ 20kHz | ±0.1% | ±0.2% | - | - | - | -30°C ~ 80°C | Bidirectional | Screw | Module | - |
|
|
Phoenix Contact |
PACT RCP-D190 |
5,130 |
|
- | AC | Transformer w/Conditioning | - | 1 | Ratiometric, Voltage | - | 40Hz ~ 20kHz | ±0.1% | ±0.2% | - | - | - | -30°C ~ 80°C | Bidirectional | Screw | Module | - |
|
|
Phoenix Contact |
PACT RCP-D95 |
8,100 |
|
- | AC | Transformer w/Conditioning | - | 1 | Ratiometric, Voltage | - | 40Hz ~ 20kHz | ±0.1% | ±0.2% | - | - | - | -30°C ~ 80°C | Bidirectional | Screw | Module | - |
|
|
Phoenix Contact |
PACT RCP-4000A-1A |
5,220 |
|
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | DIN Rail | Module | - |
|
|
Phoenix Contact |
MACX MCR-SL-CAC-12-I-UP |
5,778 |
|
* | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
|
Phoenix Contact |
SENSOR CURRENT HALL 11A AC/DC |
4,482 |
|
- | AC/DC | Hall Effect, Open Loop | 11A | 1 | Ratiometric, Voltage and Current | - | 15Hz ~ 400Hz | - | ±0.5% | 20V ~ 30V | 330ms (AC), 40ms (DC) | 40mA | -20°C ~ 60°C | Bidirectional | DIN Rail | Module | - |
|
|
Phoenix Contact |
SENSOR CURRENT HALL 55A AC/DC |
2,142 |
|
- | AC/DC | Hall Effect, Open Loop | 55A | 1 | Ratiometric, Voltage and Current | - | 15Hz ~ 400Hz | - | ±0.5% | 20V ~ 30V | 330ms (AC), 40ms (DC) | 40mA | -20°C ~ 60°C | Bidirectional | DIN Rail | Module | - |
|
|
Phoenix Contact |
SENSOR CURRENT HALL 11A AC/DC |
7,182 |
|
- | AC/DC | Hall Effect, Open Loop | 11A | 1 | Ratiometric, Voltage and Current | - | 15Hz ~ 400Hz | - | ±0.5% | 20V ~ 30V | 330ms (AC), 40ms (DC) | 50mA | -20°C ~ 60°C | Bidirectional | DIN Rail | Module | - |
|
|
Phoenix Contact |
SENSOR CURRENT HALL 55A AC/DC |
5,274 |
|
- | AC/DC | Hall Effect, Open Loop | 55A | 1 | Ratiometric, Voltage and Current | - | 15Hz ~ 400Hz | - | ±0.5% | 20V ~ 30V | 330ms (AC), 40ms (DC) | 50mA | -20°C ~ 60°C | Bidirectional | DIN Rail | Module | - |